Review



total plasma srage  (R&D Systems)


Bioz Verified Symbol R&D Systems is a verified supplier
Bioz Manufacturer Symbol R&D Systems manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 94

    Structured Review

    R&D Systems total plasma srage
    Total Plasma Srage, supplied by R&D Systems, used in various techniques. Bioz Stars score: 94/100, based on 135 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/total plasma srage/product/R&D Systems
    Average 94 stars, based on 135 article reviews
    total plasma srage - by Bioz Stars, 2026-03
    94/100 stars

    Images



    Similar Products

    94
    R&D Systems total plasma srage
    Total Plasma Srage, supplied by R&D Systems, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/total plasma srage/product/R&D Systems
    Average 94 stars, based on 1 article reviews
    total plasma srage - by Bioz Stars, 2026-03
    94/100 stars
      Buy from Supplier

    94
    R&D Systems total srage concentrations
    Effect of acute exercise intensity on soluble receptor for advanced glycation endproducts <t>(sRAGE)</t> isoforms in lean healthy adults (LH) and adults with obesity (OB). Change in plasma concentrations of <t>total</t> <t>sRAGE</t> ( A ), endogenous secretory RAGE (esRAGE, B ), and cleaved RAGE (cRAGE, C ) were calculated by subtracting values obtained at baseline (Pre) from values obtained 30 min after (Post) treadmill exercise performed at 40% of participants’ V̇ o 2max for 60 min, 65% of V̇ o 2max for 30 min, or 80% of participants’ V̇ o 2max until calorie expenditure matched that which they obtained during the 40% exercise bout. Data are represented as means ± SD, and individual data points are plotted about the mean. Data were analyzed via 2-way ANOVA with Bonferroni correction used for post hoc analyses. P values for pairwise comparisons are shown when main effects approached significance ( P < 0.05). V̇ o 2max , maximal aerobic capacity.
    Total Srage Concentrations, supplied by R&D Systems, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/total srage concentrations/product/R&D Systems
    Average 94 stars, based on 1 article reviews
    total srage concentrations - by Bioz Stars, 2026-03
    94/100 stars
      Buy from Supplier

    93
    R&D Systems total human srage
    Comparison of AGEs, <t> sRAGE </t> isoforms, and their ratios between healthy controls (CTR) and patients with type 2 diabetes
    Total Human Srage, supplied by R&D Systems, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/total human srage/product/R&D Systems
    Average 93 stars, based on 1 article reviews
    total human srage - by Bioz Stars, 2026-03
    93/100 stars
      Buy from Supplier

    90
    R&D Systems immunoassay kits for srage, which measures total immunoreactive srage, il-6 and mmp-8
    Comparison of AGEs, <t> sRAGE </t> isoforms, and their ratios between healthy controls (CTR) and patients with type 2 diabetes
    Immunoassay Kits For Srage, Which Measures Total Immunoreactive Srage, Il 6 And Mmp 8, supplied by R&D Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/immunoassay kits for srage, which measures total immunoreactive srage, il-6 and mmp-8/product/R&D Systems
    Average 90 stars, based on 1 article reviews
    immunoassay kits for srage, which measures total immunoreactive srage, il-6 and mmp-8 - by Bioz Stars, 2026-03
    90/100 stars
      Buy from Supplier

    90
    R&D Systems total srage
    Comparison of AGEs, <t> sRAGE </t> isoforms, and their ratios between healthy controls (CTR) and patients with type 2 diabetes
    Total Srage, supplied by R&D Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/total srage/product/R&D Systems
    Average 90 stars, based on 1 article reviews
    total srage - by Bioz Stars, 2026-03
    90/100 stars
      Buy from Supplier

    90
    R&D Systems total srage antigen
    Comparison of AGEs, <t> sRAGE </t> isoforms, and their ratios between healthy controls (CTR) and patients with type 2 diabetes
    Total Srage Antigen, supplied by R&D Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/total srage antigen/product/R&D Systems
    Average 90 stars, based on 1 article reviews
    total srage antigen - by Bioz Stars, 2026-03
    90/100 stars
      Buy from Supplier

    Image Search Results


    Effect of acute exercise intensity on soluble receptor for advanced glycation endproducts (sRAGE) isoforms in lean healthy adults (LH) and adults with obesity (OB). Change in plasma concentrations of total sRAGE ( A ), endogenous secretory RAGE (esRAGE, B ), and cleaved RAGE (cRAGE, C ) were calculated by subtracting values obtained at baseline (Pre) from values obtained 30 min after (Post) treadmill exercise performed at 40% of participants’ V̇ o 2max for 60 min, 65% of V̇ o 2max for 30 min, or 80% of participants’ V̇ o 2max until calorie expenditure matched that which they obtained during the 40% exercise bout. Data are represented as means ± SD, and individual data points are plotted about the mean. Data were analyzed via 2-way ANOVA with Bonferroni correction used for post hoc analyses. P values for pairwise comparisons are shown when main effects approached significance ( P < 0.05). V̇ o 2max , maximal aerobic capacity.

    Journal: Journal of Applied Physiology

    Article Title: Soluble RAGE and skeletal muscle tissue RAGE expression profiles in lean and obese young adults across differential aerobic exercise intensities

    doi: 10.1152/japplphysiol.00748.2022

    Figure Lengend Snippet: Effect of acute exercise intensity on soluble receptor for advanced glycation endproducts (sRAGE) isoforms in lean healthy adults (LH) and adults with obesity (OB). Change in plasma concentrations of total sRAGE ( A ), endogenous secretory RAGE (esRAGE, B ), and cleaved RAGE (cRAGE, C ) were calculated by subtracting values obtained at baseline (Pre) from values obtained 30 min after (Post) treadmill exercise performed at 40% of participants’ V̇ o 2max for 60 min, 65% of V̇ o 2max for 30 min, or 80% of participants’ V̇ o 2max until calorie expenditure matched that which they obtained during the 40% exercise bout. Data are represented as means ± SD, and individual data points are plotted about the mean. Data were analyzed via 2-way ANOVA with Bonferroni correction used for post hoc analyses. P values for pairwise comparisons are shown when main effects approached significance ( P < 0.05). V̇ o 2max , maximal aerobic capacity.

    Article Snippet: Total sRAGE concentrations were measured in plasma samples by commercial ELISA (DRG00, R&D Systems, Minneapolis, MN) as per the manufacturer’s protocol.

    Techniques:

    Comparison of AGEs,  sRAGE  isoforms, and their ratios between healthy controls (CTR) and patients with type 2 diabetes

    Journal: Cardiovascular Diabetology

    Article Title: Circulating levels of AGEs and soluble RAGE isoforms are associated with all-cause mortality and development of cardiovascular complications in type 2 diabetes: a retrospective cohort study

    doi: 10.1186/s12933-022-01535-3

    Figure Lengend Snippet: Comparison of AGEs, sRAGE isoforms, and their ratios between healthy controls (CTR) and patients with type 2 diabetes

    Article Snippet: Specifically, total human sRAGE included the detection of both cRAGE and esRAGE variants (DY1145, Human RAGE DuoSet ELISA, R&D Systems Inc., MN, USA) and esRAGE concentration was evaluated by an ELISA assay with an antibody raised against the exclusive C-terminal amino acids (332–347) sequence (K1009-1, B-bridge International, CA, USA). cRAGE was determined by subtracting esRAGE from sRAGE as already described [ , , ].

    Techniques:

    Boxplots for the comparison of A total sRAGE, esRAGE, and cRAGE isoforms and ) AGEs/sRAGE, AGEs/esRAGE, AGEs/cRAGE, cRAGE/esRAGE ratio among healthy control subjects (CTR) and type 2 diabetes patients without (T2DM-NC) or with (T2DM-C) complications. **p < 0.01; ***p < 0.001; ****p < 0.0001 for Dunn’s post-hoc tests following Kruskal-Wallis H test

    Journal: Cardiovascular Diabetology

    Article Title: Circulating levels of AGEs and soluble RAGE isoforms are associated with all-cause mortality and development of cardiovascular complications in type 2 diabetes: a retrospective cohort study

    doi: 10.1186/s12933-022-01535-3

    Figure Lengend Snippet: Boxplots for the comparison of A total sRAGE, esRAGE, and cRAGE isoforms and ) AGEs/sRAGE, AGEs/esRAGE, AGEs/cRAGE, cRAGE/esRAGE ratio among healthy control subjects (CTR) and type 2 diabetes patients without (T2DM-NC) or with (T2DM-C) complications. **p < 0.01; ***p < 0.001; ****p < 0.0001 for Dunn’s post-hoc tests following Kruskal-Wallis H test

    Article Snippet: Specifically, total human sRAGE included the detection of both cRAGE and esRAGE variants (DY1145, Human RAGE DuoSet ELISA, R&D Systems Inc., MN, USA) and esRAGE concentration was evaluated by an ELISA assay with an antibody raised against the exclusive C-terminal amino acids (332–347) sequence (K1009-1, B-bridge International, CA, USA). cRAGE was determined by subtracting esRAGE from sRAGE as already described [ , , ].

    Techniques:

    Spearman correlations of AGEs and the different isoforms of  sRAGE  isoforms with age in healthy controls (CTR) and patients with type 2 diabetes

    Journal: Cardiovascular Diabetology

    Article Title: Circulating levels of AGEs and soluble RAGE isoforms are associated with all-cause mortality and development of cardiovascular complications in type 2 diabetes: a retrospective cohort study

    doi: 10.1186/s12933-022-01535-3

    Figure Lengend Snippet: Spearman correlations of AGEs and the different isoforms of sRAGE isoforms with age in healthy controls (CTR) and patients with type 2 diabetes

    Article Snippet: Specifically, total human sRAGE included the detection of both cRAGE and esRAGE variants (DY1145, Human RAGE DuoSet ELISA, R&D Systems Inc., MN, USA) and esRAGE concentration was evaluated by an ELISA assay with an antibody raised against the exclusive C-terminal amino acids (332–347) sequence (K1009-1, B-bridge International, CA, USA). cRAGE was determined by subtracting esRAGE from sRAGE as already described [ , , ].

    Techniques:

    Scatter plot showing the correlation between subjects’ age and circulating A cRAGE, B AGEs/sRAGE and C AGEs/cRAGE ratios. Regression lines for CTR (green) and type 2 diabetes (T2DM, red) individuals are displayed

    Journal: Cardiovascular Diabetology

    Article Title: Circulating levels of AGEs and soluble RAGE isoforms are associated with all-cause mortality and development of cardiovascular complications in type 2 diabetes: a retrospective cohort study

    doi: 10.1186/s12933-022-01535-3

    Figure Lengend Snippet: Scatter plot showing the correlation between subjects’ age and circulating A cRAGE, B AGEs/sRAGE and C AGEs/cRAGE ratios. Regression lines for CTR (green) and type 2 diabetes (T2DM, red) individuals are displayed

    Article Snippet: Specifically, total human sRAGE included the detection of both cRAGE and esRAGE variants (DY1145, Human RAGE DuoSet ELISA, R&D Systems Inc., MN, USA) and esRAGE concentration was evaluated by an ELISA assay with an antibody raised against the exclusive C-terminal amino acids (332–347) sequence (K1009-1, B-bridge International, CA, USA). cRAGE was determined by subtracting esRAGE from sRAGE as already described [ , , ].

    Techniques:

    Age- and HbA1c-adjusted multiple quantile regression model for the evaluation of AGEs and  sRAGE  isoforms in type 2 diabetes complications

    Journal: Cardiovascular Diabetology

    Article Title: Circulating levels of AGEs and soluble RAGE isoforms are associated with all-cause mortality and development of cardiovascular complications in type 2 diabetes: a retrospective cohort study

    doi: 10.1186/s12933-022-01535-3

    Figure Lengend Snippet: Age- and HbA1c-adjusted multiple quantile regression model for the evaluation of AGEs and sRAGE isoforms in type 2 diabetes complications

    Article Snippet: Specifically, total human sRAGE included the detection of both cRAGE and esRAGE variants (DY1145, Human RAGE DuoSet ELISA, R&D Systems Inc., MN, USA) and esRAGE concentration was evaluated by an ELISA assay with an antibody raised against the exclusive C-terminal amino acids (332–347) sequence (K1009-1, B-bridge International, CA, USA). cRAGE was determined by subtracting esRAGE from sRAGE as already described [ , , ].

    Techniques:

    Univariate and multivariate Cox regression analysis for the prediction of 15-year all-cause mortality in patients with type 2 diabetes

    Journal: Cardiovascular Diabetology

    Article Title: Circulating levels of AGEs and soluble RAGE isoforms are associated with all-cause mortality and development of cardiovascular complications in type 2 diabetes: a retrospective cohort study

    doi: 10.1186/s12933-022-01535-3

    Figure Lengend Snippet: Univariate and multivariate Cox regression analysis for the prediction of 15-year all-cause mortality in patients with type 2 diabetes

    Article Snippet: Specifically, total human sRAGE included the detection of both cRAGE and esRAGE variants (DY1145, Human RAGE DuoSet ELISA, R&D Systems Inc., MN, USA) and esRAGE concentration was evaluated by an ELISA assay with an antibody raised against the exclusive C-terminal amino acids (332–347) sequence (K1009-1, B-bridge International, CA, USA). cRAGE was determined by subtracting esRAGE from sRAGE as already described [ , , ].

    Techniques: